AJAX / ocBridge Plus
incl. VAT, plus shipping costs
Receiver module for connecting Ajax detectors to wired and hybrid security systems. The device can be integrated into any central unit with wired security zones.
Product benefits
- Sends output signals via dry contact
- Can be operated in pulse and bistable mode
- Can be set via the PC configurator
Functional principle
- When the detector is activated, the device closes or opens the transistor outputs. The wired central unit records the event and triggers an alarm.
Features
- The device allows you to set up the detector and perform radio communication and detection range tests via a PC.
Installation and setup
- The device is installed in the housing of the wired central unit in sealed housings or plastic boxes.
Technical data
- Classification Wireless detector signal receiver
- Type of keypad Wireless
- Installation method In Innenräume
- Compatibility Wired and hybrid security systems
- Number of security areas 8
- Number of service areas 4
- loops NO/NC, EOL, 2EOL
- Maximum number of detectors 99
- Alarm signal detection time 0.15 sec.
- power supply voltage 8 - 14 V DC, miniUSB — 5 V (for setup only)
- Jeweller wireless technology Range for communication with detectors – up to 2000 m in open environments
Reciprocal communication between devices
Operating frequencies – 868.0–868.6 MHz
Self-adjusting RF output power – up to 25 mW
Block encryption based on the AES algorithm
Detector polling time– 12–300 sec.
- Connection option for external antenna P
- Software update function P
- operating temperature range From -10°? to +40°?
- Operating humidity Up to 90%
- Sabotage protection Protection against sabotage
Signal tampering detection
Tamper protection
- Setup and testing 107%;">Current firmware version 4.50.0
- interface Mini USB
- Maße 95 × 92 × 18 mm
- Weight 139 g
- Certification CE
Receiver module for connecting Ajax detectors to wired and hybrid security systems. The device can be integrated into any central unit with wired security zones.
- Sends output signals via dry contact
- Can be operated in pulse and bistable mode
- Can be set via the PC configurator
Functional principle
- When the detector is activated, the device closes or opens the transistor outputs. The wired central unit records the event and triggers an alarm.
Features
- The device allows you to set up the detector and perform radio communication and detection range tests via a PC.
Installation and setup
- The device is installed in the housing of the wired central unit in sealed housings or plastic boxes.
Technical data
- Classification Wireless detector signal receiver
- Type of keypad Wireless
- Installation method In Innenräume
- Compatibility Wired and hybrid security systems
- Number of security areas 8
- Number of service areas 4
- loops NO/NC, EOL, 2EOL
- Maximum number of detectors 99
- Alarm signal detection time 0.15 sec.
- power supply voltage 8 - 14 V DC, miniUSB — 5 V (for setup only)
- Jeweller wireless technology Range for communication with detectors – up to 2000 m in open environments
Reciprocal communication between devices
Operating frequencies – 868.0–868.6 MHz
Self-adjusting RF output power – up to 25 mW
Block encryption based on the AES algorithm
Detector polling time– 12–300 sec.
- Connection option for external antenna P
- Software update function P
- operating temperature range From -10°? to +40°?
- Operating humidity Up to 90%
- Sabotage protection Protection against sabotage
Signal tampering detection
Tamper protection
- Setup and testing 107%;">Current firmware version 4.50.0
- interface Mini USB
- Maße 95 × 92 × 18 mm
- Weight 139 g
- Certification CE